Eaton Power-sure 700 Line Conditioner - AC Noise, Transient, Brownout, Sag, AC Surge, Over Voltage, Overload protection - Hardwired - 208 V AC Input - 10 kVA
Eaton Power-sure 700 Line Conditioner - AC Noise, Transient, Brownout, Sag, AC Surge, Over Voltage, Overload protection - Hardwired - 208 V AC Input - 10 kVA
Eaton Power-sure 700 Line Conditioner - AC Noise, Transient, Brownout, Sag, AC Surge, Over Voltage, Overload protection - Hardwired - 208 V AC Input - 10 kVA
Photo is for Illustration purposes only. Actual Product may be different. Part Num:
TBL-010K-6Condition: Brand New$20,436.61
Add To Cart
BUY MORE & SAVE
Need 5 or more of these on a single order?
Ask for a quotation here.
We generally respond within 3 business hours.
Close
Total price is...The Eaton Power-Sure 700 three-phase power line conditioning system provides exceptional system reliability that can be attributed to Eaton's processor-controlled zero-current cross tap switching technology.
The Power-Sure 700 combines voltage regulation with a transformer and filter to remove transients and noise. The combined effect is a regulating and shielded isolation transformer/ system that solves 99 percent of the electrical disturbance problems, including electrical brownouts, sags, surges, transients and other electrical disturbances.
General Information
|
Manufacturer | Eaton Corporation |
Manufacturer Part Number | TBL-010K-6 |
Manufacturer Website Address | https://www.eaton.com/EatonCom/Markets/NorthAmerica |
Brand Name | Eaton |
Product Line | Power-Sure |
Product Model | 700 |
Product Name | Power-sure 700 Line Conditioner |
Product Type | Line Conditioner |
Technical Information
|
Protection Type | AC Noise | Transient | Brownout | Sag | AC Surge | Over Voltage | Overload |
Receptacle Type | Hardwired |
Power Description
|
Load Capacity (VA) | 10 kW |
Input Voltage | 208 V AC |
Output Voltage | 208 V AC |
Minimum Frequency | 57 Hz |
Maximum Frequency | 73 Hz |
Physical Characteristics
|
Form Factor | External |
Height | 36" (914.40 mm) |
Width | 36" (914.40 mm) |
Depth | 27" (685.80 mm) |
Weight (Approximate) | 199.58 kg |
Miscellaneous
|
Additional Information | - 10kVA 208V
- Efficiency: 97% typical, 95% minimum
- Load power factor: 0.6 leading to 0.6 lagging
- Common-mode noise attenuation: 140 dB
- Normal-mode noise attenuation: -3 dB @ 1000 Hz, -40 dBA per decade
- Total harmonic distortion: Less than 1% added
- Correction time: 1 cycle typical, 1.5 cycle maximum
- Overload rating: 200% for 10 seconds, 1000% for 1 cycle
- Over voltage protection: Automatic electronic shutdown if output voltage exceeds +10% for 6 seconds (adjustable)
|
Country of Origin | United States |
Warranty
|
Limited Warranty | 1 Year |