Black Box Outlet-Managed PDU - 1U, 20-Amp, Dual-Circuit, 120-VAC, 8-Outlet - Switched - C20 Inlet - 8 x NEMA 5-20R - 120 V AC, 230 V AC - Network (RJ-45) - 1U - Rack-mountable - TAA Compliant

Black Box Outlet-Managed PDU - 1U, 20-Amp, Dual-Circuit, 120-VAC, 8-Outlet - Switched - C20 Inlet - 8 x NEMA 5-20R - 120 V AC, 230 V AC - Network (RJ-45) - 1U - Rack-mountable - TAA Compliant
Black Box Outlet-Managed PDU - 1U, 20-Amp, Dual-Circuit, 120-VAC, 8-Outlet - Switched - C20 Inlet - 8 x NEMA 5-20R - 120 V AC, 230 V AC - Network (RJ-45) - 1U - Rack-mountable - TAA Compliant

Black Box Corporation
MPSH8-D20-120V Image
Photo is for Illustration purposes only. Actual Product may be different.
Part Num: MPSH8-D20-120V
Condition: Brand New
$2,853.00

Add To Cart

BUY MORE & SAVE

Total price is...

Quantity in stock as of last update: No



Click here to view
real-time quantity



Availability will be displayed by province.
In Stock Alert
Compare to other products
  • Generate reports with detailed records of current and power consumption.
  • Go green-save energy and money by shutting off power to equipment during downtimes.

Networks today demand 98%+ uptime. When it's your job to make sure your network equipment is up and running, Black Box® Outlet-Managed PDUs can be one of your best friends in the data center.

One of these switched PDUs will keep an eye on your network equipment no matter if you're in the office, across the country, or asleep at home at 3 a.m. You'll know if something is going wrong so you can correct the situation before it turns into a crisis. The PDU will automatically notify you via e-mail, text message, SNMP, or SYSLOG when changes in current levels, temperature, circuit breaker status, and other factors exceed threshold values that you set. This gives you the chance to reboot your rackmounted equipment when devices aren't responding; disable outlets to reduce current consumption; or even switch on cooling devices to lower the rack/cabinet temperature. You can reboot equipment over the Internet, via a text message, through an external modem, or a local terminal plugged into the RS-232 port. The PDU also features a 10/100BASE-T port for network connections.

Individual or group play.
One of the best features of these PDUs is the ability to remotely switch one outlet, a group, or a branch, or to switch a whole group of outlets. You can also set the PDU to monitor one outlet, a group, or a branch of outlets.

Sound the alarm.
The PDU boasts a robust selection of monitoring features to help you keep tabs on vital network equipment, avoid costly service calls, and maximize uptime. You can customize the PDU to your network by selecting the alarms and setting individual thresholds.

Use the PDU to alert you when:

  • The temperature gets too high.
  • An outlet is on, but the connected device is off.
  • The power supply has been interrupted.
  • Current consumption increases or decreases.
  • An outlet draws excessive current.
  • Equipment fails to respond to ping commands.
  • Excessive invalid passwords are attempted.

Power down.
Another great feature of these switched PDUs is that you can set them to respond automatically in case you're not there. Set the parameters for the PDUs to disable outlets to reduce current consumption or to switch on cooling devices. If the current load goes too high, it intelligently sheds load by temporarily shutting down non-essential devices.

Anyone home?
You can also set the PDU to ping equipment at set intervals. If the equipment doesn't respond, the PDU automatically reboots the outlets. You can also set alarms in case you lose communications on the ports.

Security guard.
Plus, you can use the PDU to alert you when there are multiple login attempts on the 10/100 network and serial ports. The PDU features SSHv2 encryption, HTTPS/SSL secure Web, and an embedded validation FIPS 140-2 cryptographic module. It also offers multiple methods of remote authentication: LDAP, Kerberos, RADIUS, and TACACS+. Additionally, it has IP address filtering and four levels of security for user accounts with plug-specific password protection.

Go green and save power.
Use the Outlet-Managed PDU to conserve energy in the data center by setting scheduled shutdowns to turn off unused equipment during off hours.

General Information
Manufacturer

Black Box Corporation

Manufacturer Part Number

MPSH8-D20-120V

Manufacturer Website Address

https://www.blackbox.com

Brand Name

Black Box

Product Name

8-Outlets PDU

Product Condition

New

Product Type

PDU


 
Technical Information
PDU Type

Switched

Plug/Connector Type

C20 Inlet

Plug/Connector Detail

1 x C20 Inlet

Receptacle Type

NEMA 5-20R

Receptacle Detail

8 x NEMA 5-20R

Protection Type

Password Protection   |   Circuit Protection   |   Over Temperature


 
Power Description
Input Voltage

120 V AC   |   230 V AC

Input Voltage Range

100 V AC - 250 V AC

Input Current

32 A


 
Management
Management

  • SSHv2
  • HTTPS/SSL
  • LDAP
  • Kerberos
  • RADIUS,
  • TACACS+
  • SNMP
  • SYSLOG

Remote Outlet Switching

Yes


 
Interfaces/Ports
Network (RJ-45)

Yes


 
Physical Characteristics
Mount Type

Rack-mountable

Rack Height

1U

Height

1.75" (44.45 mm)

Width

19" (482.60 mm)

Depth

8.70" (220.98 mm)

Weight (Approximate)

4.99 kg


 
Miscellaneous
Environmentally Friendly

Yes

Country of Origin

United States

TAA Compliant

Yes


 
Warranty
Limited Warranty

5 Year


 
 